Olympian® Series 64 Oil Vapour Removal Ultraire Filter® 1/2BSPP

Stock Code: NORGREN-F64B-4GN-AR0

Call

  • Olympian Plus plug in design
  • Combined oil and vapour removal filter
  • Oil mist contamination in outlet air, normally complies with BS4275 (1974)†
  • Oil and dirt contamination in outlet air within ISO 8573-1: Quality class 1.7.1

    Technical Data Summary
    Specification Details  
    Body Zinc
    Bowl Zinc
    Elastomers Synthetic Rubber
    Design Structure  
      Auto Drain
    Port Size  
      1/2 BSPP
    Operating Temperature  
      -20°c to +65°c
    Flow  
      11dm3/s
    Operating Medium  
      Compressed Air
    Maximum Pressure  
      17 Bar
    Filter Element  
      0.01µm Activated Carbon and Polycarbonate
  • Name File Name
    Norgren Olympian Ultraire 64 Norgren Olympian Ultraire 64.pdf